For advice on the specification or use of Hush-Slab 100 within any project, please contact our experienced technical team on 0151 933 2026 who will be happy to give comprehensive and tailored advice to meet with your requirements.
Safety
Use protective gloves when handling - beware of sharp edges
Test Data
Test data for field tests in compliance with Building Regulations Document E can be supplied upon request.
Product Data
Application |
In between floor and ceiling joists and wall studs to suit system requirements. |
Comprises |
High density mineral fibre produced from non-combustible inorganic rock it is defined as 'mineral wool' in BS 3533 and complies fully with the recommendations of BS 5422 and BS 3958: Part 5.
|
Durability |
Will not encourage the growth of fungi, mould or bacteria, does not sustain vermin, is rot-proof, odourless and completely non-hygroscopic. |
Fire Performance |
Non-combustible, Class 'O' to Building Regulations achieving both a Class 1 Spread of Flame to BS 476: Part 7 and the required indices of performance of fire propagation to BS 476: Part 6. |
Compatible Hush-Systems |
Hush-System 2003, Hush-System 2003 Plus, Hush-System 2003 Advanced, Hush-System 1, Hush-System IC, Hush-System HF25, Hush-System HF25 Advanced. |
Thicknesses available
mm |
Thermal Conductivity
W/mK
|
Thermal resistance
m²K/W |
Slab size
mm |
Slabs
per pack |
Area
per pack
m² |
100 |
0.035 |
2.85 |
1200x600 |
5 |
3.6 |
75 |
0.035 |
2.10 |
1200x600 |
8 |
5.76 |
50 |
0.035 |
1.40 |
1200x600 |
12 |
8.64 |
25 |
0.035 |
0.70 |
1200x600 |
18 |
12.96 |
Cut the Hush-Slabs to the required void width using a sharp saw or long blade, and starting at one of the room perimeters, begin fitting the slabs in between the floor joists or wall studs. At the end of each run, cut the last slab to the required length and then continue the process until all voids are filled, ensuring there are no gaps. Any excess trimmings can be used to pack in alongside the full slabs, avoiding any waste. Hush-Slabs can be friction fitted from below when using within a ceiling system.
Full fitting instructions are supplied with all products and are available to download from the Installation Guides section.
Should you have any technical questions prior to or during installation, please call 0151 933 2026 for friendly and straightforward advice.