44 Canal Street,
South Sefton,
Merseyside, L20 8QU
1. When fitting to bare joists screw 9mm plywood to the underside to support the Hush-Fill. To existing joists, where the ceiling is to remain in place, fit noggins/dwangs in between the joists and construct a shelf with 9mm plywood or similar.
2. The Hush-Fill tubes are then laid over the plywood. Slit the bags and ensure that all areas are covered to a consistent depth of 60mm. The bags are left in place as liners.
3. A consistent 60mm depth must always be achieved and the bags have printed instructions on how to adjust if joist centres vary.
Full fitting instructions are supplied with all products and are available to download from the Installation Guides section.
Should you have any technical questions prior to or during installation, please call 0151 933 2026 for friendly and straightforward advice.